{"id":345,"date":"2023-12-20T10:18:22","date_gmt":"2023-12-20T10:18:22","guid":{"rendered":"https:\/\/www.veratech.es\/?p=345"},"modified":"2024-01-02T14:02:27","modified_gmt":"2024-01-02T14:02:27","slug":"pueden-openehr-iso-13606-y-hl7-fhir-funcionar-juntos-una-perspectiva-agnostica-para-la-seleccion-y-aplicacion-de-estandares-de-hce-en-espana","status":"publish","type":"post","link":"http:\/\/veratech.es\/en\/2023\/12\/20\/pueden-openehr-iso-13606-y-hl7-fhir-funcionar-juntos-una-perspectiva-agnostica-para-la-seleccion-y-aplicacion-de-estandares-de-hce-en-espana\/","title":{"rendered":"Can OpenEHR, ISO 13606, and HL7 FHIR work together? An agnostic perspective for the selection and application of EHR standards in Spain."},"content":{"rendered":"<p>Due to the heterogeneity of Electronic Health Record (EHR) standards, decision-making teams, who are not experts in health information, express confusion in selecting and applying these resources in their data platforms. Therefore, a group of experts has analyzed the strengths and weaknesses regarding the design, modeling capabilities, flexibility, and implemented resources of three relevant standards based on Detailed Clinical Models: OpenEHR, ISO 13606, and HL7 FHIR. Thus, it was concluded that: (1) they are useful for the purposes for which they have been designed and present deficiencies in those for which they have not been designed; (2) they are functionally compatible in platforms and health data methodologies developed from an independent perspective of the standards; and (3) they are conceptually and technically compatible with each other, so the choice of one or the other does not have a high impact as long as it starts from the one richer in modeling capabilities and flexibility.<\/p>","protected":false},"excerpt":{"rendered":"<p>Debido a la heterogeneidad de los est\u00e1ndares de Historia Cl\u00ednica Electr\u00f3nica (HCE), los equipos de toma de decisiones, que no son expertos en informaci\u00f3n de salud, expresan confusi\u00f3n para seleccionar y aplicar estos recursos en sus plataformas de datos. Por ello, un grupo de expertos ha analizado las fortalezas y debilidades sobre el dise\u00f1o, las capacidades de modelado, la flexibilidad y los recursos implementados de tres est\u00e1ndares [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":0,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[12],"tags":[37,38],"class_list":["post-345","post","type-post","status-publish","format-standard","hentry","category-knowledge_center","tag-https-www-researchgate-net-publication-360857878_can_openehr_iso_13606_and_hl7_fhir_w_the_selection_and_application_of_ehr_standards_from_spain","tag-openehr-iso-13606-hl7-fhir"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v27.4 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>\u00bfPueden OpenEHR, ISO 13606 y HL7 FHIR funcionar juntos? Una perspectiva agn\u00f3stica para la selecci\u00f3n y aplicaci\u00f3n de est\u00e1ndares de HCE en Espa\u00f1a. - Veratech for Health<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/veratech.es\/en\/2023\/12\/20\/pueden-openehr-iso-13606-y-hl7-fhir-funcionar-juntos-una-perspectiva-agnostica-para-la-seleccion-y-aplicacion-de-estandares-de-hce-en-espana\/\" \/>\n<meta property=\"og:locale\" content=\"en_GB\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"\u00bfPueden OpenEHR, ISO 13606 y HL7 FHIR funcionar juntos? Una perspectiva agn\u00f3stica para la selecci\u00f3n y aplicaci\u00f3n de est\u00e1ndares de HCE en Espa\u00f1a. - Veratech for Health\" \/>\n<meta property=\"og:description\" content=\"Debido a la heterogeneidad de los est\u00e1ndares de Historia Cl\u00ednica Electr\u00f3nica (HCE), los equipos de toma de decisiones, que no son expertos en informaci\u00f3n de salud, expresan confusi\u00f3n para seleccionar y aplicar estos recursos en sus plataformas de datos. Por ello, un grupo de expertos ha analizado las fortalezas y debilidades sobre el dise\u00f1o, las capacidades de modelado, la flexibilidad y los recursos implementados de tres est\u00e1ndares [&hellip;]\" \/>\n<meta property=\"og:url\" content=\"https:\/\/veratech.es\/en\/2023\/12\/20\/pueden-openehr-iso-13606-y-hl7-fhir-funcionar-juntos-una-perspectiva-agnostica-para-la-seleccion-y-aplicacion-de-estandares-de-hce-en-espana\/\" \/>\n<meta property=\"og:site_name\" content=\"Veratech for Health\" \/>\n<meta property=\"article:published_time\" content=\"2023-12-20T10:18:22+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2024-01-02T14:02:27+00:00\" \/>\n<meta name=\"author\" content=\"veraweb23update\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:creator\" content=\"@veratech\" \/>\n<meta name=\"twitter:site\" content=\"@veratech\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"veraweb23update\" \/>\n\t<meta name=\"twitter:label2\" content=\"Estimated reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"1 minute\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/veratech.es\\\/en\\\/2023\\\/12\\\/20\\\/pueden-openehr-iso-13606-y-hl7-fhir-funcionar-juntos-una-perspectiva-agnostica-para-la-seleccion-y-aplicacion-de-estandares-de-hce-en-espana\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/veratech.es\\\/en\\\/2023\\\/12\\\/20\\\/pueden-openehr-iso-13606-y-hl7-fhir-funcionar-juntos-una-perspectiva-agnostica-para-la-seleccion-y-aplicacion-de-estandares-de-hce-en-espana\\\/\"},\"author\":{\"name\":\"veraweb23update\",\"@id\":\"https:\\\/\\\/veratech.es\\\/#\\\/schema\\\/person\\\/205ab530575337ab02ada32882b4087c\"},\"headline\":\"\u00bfPueden OpenEHR, ISO 13606 y HL7 FHIR funcionar juntos? Una perspectiva agn\u00f3stica para la selecci\u00f3n y aplicaci\u00f3n de est\u00e1ndares de HCE en Espa\u00f1a.\",\"datePublished\":\"2023-12-20T10:18:22+00:00\",\"dateModified\":\"2024-01-02T14:02:27+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/veratech.es\\\/en\\\/2023\\\/12\\\/20\\\/pueden-openehr-iso-13606-y-hl7-fhir-funcionar-juntos-una-perspectiva-agnostica-para-la-seleccion-y-aplicacion-de-estandares-de-hce-en-espana\\\/\"},\"wordCount\":202,\"publisher\":{\"@id\":\"https:\\\/\\\/veratech.es\\\/#organization\"},\"keywords\":[\"https:\\\/\\\/www.researchgate.net\\\/publication\\\/360857878_Can_OpenEHR_ISO_13606_and_HL7_FHIR_w[\u2026]_the_selection_and_application_of_EHR_standards_from_Spain\",\"OpenEHR - ISO 13606 - HL7 FHIR\"],\"articleSection\":[\"Knowledge_center\"],\"inLanguage\":\"en-GB\"},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/veratech.es\\\/en\\\/2023\\\/12\\\/20\\\/pueden-openehr-iso-13606-y-hl7-fhir-funcionar-juntos-una-perspectiva-agnostica-para-la-seleccion-y-aplicacion-de-estandares-de-hce-en-espana\\\/\",\"url\":\"https:\\\/\\\/veratech.es\\\/en\\\/2023\\\/12\\\/20\\\/pueden-openehr-iso-13606-y-hl7-fhir-funcionar-juntos-una-perspectiva-agnostica-para-la-seleccion-y-aplicacion-de-estandares-de-hce-en-espana\\\/\",\"name\":\"\u00bfPueden OpenEHR, ISO 13606 y HL7 FHIR funcionar juntos? Una perspectiva agn\u00f3stica para la selecci\u00f3n y aplicaci\u00f3n de est\u00e1ndares de HCE en Espa\u00f1a. - Veratech for Health\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/veratech.es\\\/#website\"},\"datePublished\":\"2023-12-20T10:18:22+00:00\",\"dateModified\":\"2024-01-02T14:02:27+00:00\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/veratech.es\\\/en\\\/2023\\\/12\\\/20\\\/pueden-openehr-iso-13606-y-hl7-fhir-funcionar-juntos-una-perspectiva-agnostica-para-la-seleccion-y-aplicacion-de-estandares-de-hce-en-espana\\\/#breadcrumb\"},\"inLanguage\":\"en-GB\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/veratech.es\\\/en\\\/2023\\\/12\\\/20\\\/pueden-openehr-iso-13606-y-hl7-fhir-funcionar-juntos-una-perspectiva-agnostica-para-la-seleccion-y-aplicacion-de-estandares-de-hce-en-espana\\\/\"]}]},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/veratech.es\\\/en\\\/2023\\\/12\\\/20\\\/pueden-openehr-iso-13606-y-hl7-fhir-funcionar-juntos-una-perspectiva-agnostica-para-la-seleccion-y-aplicacion-de-estandares-de-hce-en-espana\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Portada\",\"item\":\"https:\\\/\\\/veratech.es\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"\u00bfPueden OpenEHR, ISO 13606 y HL7 FHIR funcionar juntos? Una perspectiva agn\u00f3stica para la selecci\u00f3n y aplicaci\u00f3n de est\u00e1ndares de HCE en Espa\u00f1a.\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/veratech.es\\\/#website\",\"url\":\"https:\\\/\\\/veratech.es\\\/\",\"name\":\"Veratech for Health\",\"description\":\"Somos una consultor\u00eda de interoperabilidad sem\u00e1ntica que te ayuda a gestionar tus datos\",\"publisher\":{\"@id\":\"https:\\\/\\\/veratech.es\\\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/veratech.es\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-GB\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/veratech.es\\\/#organization\",\"name\":\"Veratech for Health\",\"url\":\"https:\\\/\\\/veratech.es\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-GB\",\"@id\":\"https:\\\/\\\/veratech.es\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/veratech.es\\\/wp-content\\\/uploads\\\/2025\\\/03\\\/VT_15Aniversario.png\",\"contentUrl\":\"https:\\\/\\\/veratech.es\\\/wp-content\\\/uploads\\\/2025\\\/03\\\/VT_15Aniversario.png\",\"width\":1920,\"height\":538,\"caption\":\"Veratech for Health\"},\"image\":{\"@id\":\"https:\\\/\\\/veratech.es\\\/#\\\/schema\\\/logo\\\/image\\\/\"},\"sameAs\":[\"https:\\\/\\\/x.com\\\/veratech\",\"https:\\\/\\\/www.linkedin.com\\\/company\\\/2261467\\\/admin\\\/dashboard\\\/\"]},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/veratech.es\\\/#\\\/schema\\\/person\\\/205ab530575337ab02ada32882b4087c\",\"name\":\"veraweb23update\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-GB\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/68854fecc296ff46e6e2697dbc6f148ffba060959fd4c460dd6e5005601b2e09?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/68854fecc296ff46e6e2697dbc6f148ffba060959fd4c460dd6e5005601b2e09?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/68854fecc296ff46e6e2697dbc6f148ffba060959fd4c460dd6e5005601b2e09?s=96&d=mm&r=g\",\"caption\":\"veraweb23update\"},\"sameAs\":[\"http:\\\/\\\/localhost\\\/veratech-web\"],\"url\":\"http:\\\/\\\/veratech.es\\\/en\\\/author\\\/veraweb23update\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"\u00bfPueden OpenEHR, ISO 13606 y HL7 FHIR funcionar juntos? Una perspectiva agn\u00f3stica para la selecci\u00f3n y aplicaci\u00f3n de est\u00e1ndares de HCE en Espa\u00f1a. - Veratech for Health","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/veratech.es\/en\/2023\/12\/20\/pueden-openehr-iso-13606-y-hl7-fhir-funcionar-juntos-una-perspectiva-agnostica-para-la-seleccion-y-aplicacion-de-estandares-de-hce-en-espana\/","og_locale":"en_GB","og_type":"article","og_title":"\u00bfPueden OpenEHR, ISO 13606 y HL7 FHIR funcionar juntos? Una perspectiva agn\u00f3stica para la selecci\u00f3n y aplicaci\u00f3n de est\u00e1ndares de HCE en Espa\u00f1a. - Veratech for Health","og_description":"Debido a la heterogeneidad de los est\u00e1ndares de Historia Cl\u00ednica Electr\u00f3nica (HCE), los equipos de toma de decisiones, que no son expertos en informaci\u00f3n de salud, expresan confusi\u00f3n para seleccionar y aplicar estos recursos en sus plataformas de datos. Por ello, un grupo de expertos ha analizado las fortalezas y debilidades sobre el dise\u00f1o, las capacidades de modelado, la flexibilidad y los recursos implementados de tres est\u00e1ndares [&hellip;]","og_url":"https:\/\/veratech.es\/en\/2023\/12\/20\/pueden-openehr-iso-13606-y-hl7-fhir-funcionar-juntos-una-perspectiva-agnostica-para-la-seleccion-y-aplicacion-de-estandares-de-hce-en-espana\/","og_site_name":"Veratech for Health","article_published_time":"2023-12-20T10:18:22+00:00","article_modified_time":"2024-01-02T14:02:27+00:00","author":"veraweb23update","twitter_card":"summary_large_image","twitter_creator":"@veratech","twitter_site":"@veratech","twitter_misc":{"Written by":"veraweb23update","Estimated reading time":"1 minute"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/veratech.es\/en\/2023\/12\/20\/pueden-openehr-iso-13606-y-hl7-fhir-funcionar-juntos-una-perspectiva-agnostica-para-la-seleccion-y-aplicacion-de-estandares-de-hce-en-espana\/#article","isPartOf":{"@id":"https:\/\/veratech.es\/en\/2023\/12\/20\/pueden-openehr-iso-13606-y-hl7-fhir-funcionar-juntos-una-perspectiva-agnostica-para-la-seleccion-y-aplicacion-de-estandares-de-hce-en-espana\/"},"author":{"name":"veraweb23update","@id":"https:\/\/veratech.es\/#\/schema\/person\/205ab530575337ab02ada32882b4087c"},"headline":"\u00bfPueden OpenEHR, ISO 13606 y HL7 FHIR funcionar juntos? Una perspectiva agn\u00f3stica para la selecci\u00f3n y aplicaci\u00f3n de est\u00e1ndares de HCE en Espa\u00f1a.","datePublished":"2023-12-20T10:18:22+00:00","dateModified":"2024-01-02T14:02:27+00:00","mainEntityOfPage":{"@id":"https:\/\/veratech.es\/en\/2023\/12\/20\/pueden-openehr-iso-13606-y-hl7-fhir-funcionar-juntos-una-perspectiva-agnostica-para-la-seleccion-y-aplicacion-de-estandares-de-hce-en-espana\/"},"wordCount":202,"publisher":{"@id":"https:\/\/veratech.es\/#organization"},"keywords":["https:\/\/www.researchgate.net\/publication\/360857878_Can_OpenEHR_ISO_13606_and_HL7_FHIR_w[\u2026]_the_selection_and_application_of_EHR_standards_from_Spain","OpenEHR - ISO 13606 - HL7 FHIR"],"articleSection":["Knowledge_center"],"inLanguage":"en-GB"},{"@type":"WebPage","@id":"https:\/\/veratech.es\/en\/2023\/12\/20\/pueden-openehr-iso-13606-y-hl7-fhir-funcionar-juntos-una-perspectiva-agnostica-para-la-seleccion-y-aplicacion-de-estandares-de-hce-en-espana\/","url":"https:\/\/veratech.es\/en\/2023\/12\/20\/pueden-openehr-iso-13606-y-hl7-fhir-funcionar-juntos-una-perspectiva-agnostica-para-la-seleccion-y-aplicacion-de-estandares-de-hce-en-espana\/","name":"\u00bfPueden OpenEHR, ISO 13606 y HL7 FHIR funcionar juntos? Una perspectiva agn\u00f3stica para la selecci\u00f3n y aplicaci\u00f3n de est\u00e1ndares de HCE en Espa\u00f1a. - Veratech for Health","isPartOf":{"@id":"https:\/\/veratech.es\/#website"},"datePublished":"2023-12-20T10:18:22+00:00","dateModified":"2024-01-02T14:02:27+00:00","breadcrumb":{"@id":"https:\/\/veratech.es\/en\/2023\/12\/20\/pueden-openehr-iso-13606-y-hl7-fhir-funcionar-juntos-una-perspectiva-agnostica-para-la-seleccion-y-aplicacion-de-estandares-de-hce-en-espana\/#breadcrumb"},"inLanguage":"en-GB","potentialAction":[{"@type":"ReadAction","target":["https:\/\/veratech.es\/en\/2023\/12\/20\/pueden-openehr-iso-13606-y-hl7-fhir-funcionar-juntos-una-perspectiva-agnostica-para-la-seleccion-y-aplicacion-de-estandares-de-hce-en-espana\/"]}]},{"@type":"BreadcrumbList","@id":"https:\/\/veratech.es\/en\/2023\/12\/20\/pueden-openehr-iso-13606-y-hl7-fhir-funcionar-juntos-una-perspectiva-agnostica-para-la-seleccion-y-aplicacion-de-estandares-de-hce-en-espana\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Portada","item":"https:\/\/veratech.es\/"},{"@type":"ListItem","position":2,"name":"\u00bfPueden OpenEHR, ISO 13606 y HL7 FHIR funcionar juntos? Una perspectiva agn\u00f3stica para la selecci\u00f3n y aplicaci\u00f3n de est\u00e1ndares de HCE en Espa\u00f1a."}]},{"@type":"WebSite","@id":"https:\/\/veratech.es\/#website","url":"https:\/\/veratech.es\/","name":"Veratech for Health","description":"Somos una consultor\u00eda de interoperabilidad sem\u00e1ntica que te ayuda a gestionar tus datos","publisher":{"@id":"https:\/\/veratech.es\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/veratech.es\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-GB"},{"@type":"Organization","@id":"https:\/\/veratech.es\/#organization","name":"Veratech for Health","url":"https:\/\/veratech.es\/","logo":{"@type":"ImageObject","inLanguage":"en-GB","@id":"https:\/\/veratech.es\/#\/schema\/logo\/image\/","url":"https:\/\/veratech.es\/wp-content\/uploads\/2025\/03\/VT_15Aniversario.png","contentUrl":"https:\/\/veratech.es\/wp-content\/uploads\/2025\/03\/VT_15Aniversario.png","width":1920,"height":538,"caption":"Veratech for Health"},"image":{"@id":"https:\/\/veratech.es\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/x.com\/veratech","https:\/\/www.linkedin.com\/company\/2261467\/admin\/dashboard\/"]},{"@type":"Person","@id":"https:\/\/veratech.es\/#\/schema\/person\/205ab530575337ab02ada32882b4087c","name":"veraweb23update","image":{"@type":"ImageObject","inLanguage":"en-GB","@id":"https:\/\/secure.gravatar.com\/avatar\/68854fecc296ff46e6e2697dbc6f148ffba060959fd4c460dd6e5005601b2e09?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/68854fecc296ff46e6e2697dbc6f148ffba060959fd4c460dd6e5005601b2e09?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/68854fecc296ff46e6e2697dbc6f148ffba060959fd4c460dd6e5005601b2e09?s=96&d=mm&r=g","caption":"veraweb23update"},"sameAs":["http:\/\/localhost\/veratech-web"],"url":"http:\/\/veratech.es\/en\/author\/veraweb23update\/"}]}},"_links":{"self":[{"href":"http:\/\/veratech.es\/en\/wp-json\/wp\/v2\/posts\/345","targetHints":{"allow":["GET"]}}],"collection":[{"href":"http:\/\/veratech.es\/en\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"http:\/\/veratech.es\/en\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"http:\/\/veratech.es\/en\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"http:\/\/veratech.es\/en\/wp-json\/wp\/v2\/comments?post=345"}],"version-history":[{"count":1,"href":"http:\/\/veratech.es\/en\/wp-json\/wp\/v2\/posts\/345\/revisions"}],"predecessor-version":[{"id":346,"href":"http:\/\/veratech.es\/en\/wp-json\/wp\/v2\/posts\/345\/revisions\/346"}],"wp:attachment":[{"href":"http:\/\/veratech.es\/en\/wp-json\/wp\/v2\/media?parent=345"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"http:\/\/veratech.es\/en\/wp-json\/wp\/v2\/categories?post=345"},{"taxonomy":"post_tag","embeddable":true,"href":"http:\/\/veratech.es\/en\/wp-json\/wp\/v2\/tags?post=345"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}